Send inquiry
CNS114 Series Pure Sine Wave Hybrid Charger Inverter 4~5KVA
CNS114 is equipped with MPPT solar charger controller to maximize and regulate DC power from colar array for charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it is worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TVs, cmputers, power tool and battery chargers.
Features:
Pure sine wave inverter.
Built-in MPPT solar charge controller.
Selectable charging current based on applications.
Configurable AC/Solar input priority via LCD setting.
Compatible to mains voltage or generator power.
Auto restart while AC is recovering.
Overload and short circuit protection.
Smart battery charger design for optimized battery performance.
Cold start function.
Parallel operation with up to 6 units only available for 4KVA/5KVA
Optinal Remote Control Panel available.
Pure Sine Wave Hybrid Charger Inverter
Specifications
Product specifications are subject to change without further notice.
CNS114 is equipped with MPPT solar charger controller to maximize and regulate DC power from colar array for charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it is worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TVs, cmputers, power tool and battery chargers.
Features:
Pure sine wave inverter.
Built-in MPPT solar charge controller.
Selectable charging current based on applications.
Configurable AC/Solar input priority via LCD setting.
Compatible to mains voltage or generator power.
Auto restart while AC is recovering.
Overload and short circuit protection.
Smart battery charger design for optimized battery performance.
Cold start function.
Parallel operation with up to 6 units only available for 4KVA/5KVA
Optinal Remote Control Panel available.
Pure Sine Wave Hybrid Charger Inverter
Specifications
Model | CNS114 4000-48 | CNS114 5000-48 | |
AC Input | Nominal Pwer | 4000VA/3200W | 5000VA/4000W |
Nominal input voltage | 230VAC | ||
Low Line Disconnect | 170Vac±4%(Normal) or 90Vac±4% (Wide&Gen) | ||
Low Line Re-connect | 180Vac±4%(Normal) or 100Vac±4%(Wide&Gen) | ||
High Line Disconnect | 280Vac±4%(Normal) or 280Vac±4%(Wide&Gen) | ||
High Line Re-connect | 275 Vac±4%(Normal) or 275Vac±4%(Wide&Gen) | ||
Max AC Input Voltage | Max:300VAC | ||
Frequency | 50Hz/60Hz(Autodetection) | ||
AC Output | AC Voltage Regulation (Batt.Mode) |
230VAC±5% | |
Output Voltage Waveform | Pure sine wave | ||
Surge Power | 8000VA | 10000VA | |
Transfer Time | 10ms(for personal computer); 20ms(for home appliances) |
||
Full load efficiency | 93% | ||
Solar charger & AC charger | Maximun PV Array Power | 4000W | |
MPPT Range Operating Voltage |
60VDC~115VDC | ||
Maximun PV Array Open Circuit Voltage |
145VDC | ||
Maximun Solar Charge Current | 80A | ||
Maximun AC Charge Current | 60A | ||
Maximun Charge Current | 140A | ||
Standby Power Consumption | 2W | ||
Efficiency | 98% | ||
Battery& AC charger | Battery Voltage | 48VDC | |
Floating Charge Voltage | 54VDC | ||
Overcharge Protection | 60VDC | ||
General specifications | Operating Temperature Range | 0ºC~5ºC | |
Storage Temperature | -15ºC~60ºC | ||
Operation humidity | 5% to 95% Reletive Humidity (non condensing) |
||
Dimention(L*W*H) | 120*295*468mm | ||
Net Weight(kg) | 11kg |