Tfc-1000L 100MHz-1GHz Multi-Function and Other Precision Frequency Meter

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-17 12:31

  • Browse the number:

    83

Send an inquiries

Company Profile

Dongguan Longwei Electronic Technology Co., Ltd.

By certification [File Integrity]

Contact:Mr. Edison Huang(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website: http://dglongwei.better-elec.com/

Product details
TFC-1000L 100Mhz-1Ghz Multi-function and other precision frequency meter
Features:
Novel style, lightweight.
Cycle cumulative measurement.
Both importations frequency ranges: 10Hz to 1 GHz
Highest input sensitivity: 20mVrms.
8 high brightness LED display windows, 0 to 9 characters display simultaneously in cycle a self-test function.
Stability:±3*10-9s
Specifications: 
1. Measurement methods
(1) Frequency measurement
A channel
Range: 10Hz-10MHz (Direct count)
10MHz-100MHz (proportion count)
Direct count:1Hz ,10Hz,100Hz(your choice)
proportion count:10Hz ,100Hz,1000Hz(your choice)
Strobe time: 0.01s,0.1s,1s (your choice)
Accuracy: ±count value± base time error ×measured frequency
B channel
Nominal Mode TFC1000L
Range 100MHz-1GHz
Resolution 100Hz,1KHz,10KHz
Strobe time 0.01s,0.1s1s
Accuracy Accuracy: ±count value± base time error ×measured frequency
period measurement
Input: A channel
Range: 10Hz-10MHz
Resolution: 10-7s, 10 -8s, 10 -9s (your choice)
Accuracy: ±count value± base time error ×measured frequency
(3)accumulate measurement
Input: A channel
Range: 10Hz-10MHz
Accuracy: ±1 count impulse
Self-check
Monitor: 0-9 characters of 8 digital pipe repeatedly shows
2. Input characteristics
 (1)A channel
Input sensitivity: (10MHz) range: 10Hz-8MHz 20mVrms
8MHz-10MHz 30mVrms
(100MHz) range: 10MHz-8MHz 20mVrms
80MHz-100MHz 30mVrms
Attenuation: ×1, ×20 fixed
Wave filtering: low pass, 100KHz,-3dB
Impedance&colon; about 1 M&ohm; &lpar;<35PF&rpar;
Max&period; Safety voltage&colon; 250V &lpar;DC&plus;AC rms&rpar;
&lpar;2&rpar;B channel
Input sensitivity&colon; 20mVrms
Impedance&colon; about 50 &ohm;
Max&period; Safety voltage&colon; 3V
3&period; Time base
 Time base frequency&colon; 10MHz
Short-term stability&colon; ±3×10-9&sol;s
Long -term stability&colon; ±2×10-5&sol;s
Temperature Coefficient&colon; ±1×10-5&comma; 00C-400C
Line voltage&colon; Each change ± 10&percnt;&comma; the frequency variation ± 1 x 10-7 correspond
4&period; Power supply voltage&colon; AC220± 10&percnt; 50Hz
5&period; Start time&colon; 20 minutes &lpar;<250C&rpar;
6&period; Temperature&colon; working temperature -50C-500C
Storage and transportation temperature&colon;-400C-600C
7&period;Humidity&colon;Working Humidity&colon; 10-90&percnt; RH
Storage Humidity&colon; 5-95&percnt; RH
8&period; Dimension&colon; 230&ast;200&ast;75 mm
9&period;Weight &colon;2Kg