Zgs11-630kVA Prefabricated Substation/10kv American-Type Transformer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Anhui

  • Validity to:

    Long-term effective

  • Last update:

    2017-11-11 09:24

  • Browse the number:

    218

Send an inquiries

Company Profile

Anhui Wanxiang Electrical Equipment Co., Ltd.

By certification [File Integrity]

Contact:Mr. Ice Yuan(Mr.)  

Email:

Telephone:

Phone:

Area:Anhui

Address:Anhui

Website: http://anhuiwanxiang.better-elec.com/

Product details


 
  1. The use of special connection mode, when the transformer high voltage side has a fuse fusing, the low voltage side of transformer non fault phase can still maintain normal voltage of power supply.
  2. Its characteristics are that complete sets of strong, reliable power supply, small size, light weight, low noise.
  3. Oil tank is fully sealed structure,no oil storage tank, the tank of the oil is isolated,no leakage.
  4. Fuse and high voltage load switch, non-field excitation changer tap-changer as transformer components are in the transformer oil tank.
  5. Have a good safety. High voltage room is fully insulated, High voltage room and low voltage room is separated, Take the interlocking. After you open the low voltage room door ,you can open the high voltage room door .
10KV level ZGS9-H(Z) Combined transformer technology parameters
nominal capacity(KVA) Voltage combination Join group label No-load loss(KW)  load loss(KW) No-load current(%) Short circuit impedance
HV(KV) High voltage range LV(KV)
50 6
6.3
6.6
10
10.511
±5% 0.4 Dyn11/Yyn0 0.17 0.91/0.87 2.0 4
63 0.20 1.09/1.04 1.9 4
80 0.25 1.31/1.25 1.9 4
100 0.29 1.58/1.50 1.8 4
125 0.34 1.89/1.80 1.7 4
160 0.40 2.31/2.20 1.6 4
200 0.48 2.73/2.60 1.5 4
250 0.56 3.2/3.05 1.4 4
315 0.67 3.83/3.65 1.4 4
400 0.80 4.52/4.30 1.3 4
500 0.96 5.41/5.15 1.2 4
630 1.20 6.20 1.1 4.5
800 1.40 7.50 1.0 4.5
1000 1.70 10.30 1.0 4.5
1250 1.95 12.00 0.9 4.5
1600 2.40 14.50 0.8 4.5

10KV level ZGS11-H(Z) Combined transformer technology parameters
nominal capacity(KVA) Voltage combination Join group label No-load loss(KW)  load loss(KW) No-load current(%) Short circuit impedance
HV(KV) High voltage range LV(KV)
50 6
6.3
6.6
10
10.511
±5% 0.4 Dyn11/Yyn0 0.13 0.91/0.87 2.0 4
63 0.15 1.09/1.04 1.9 4
80 0.18 1.31/1.25 1.9 4
100 0.20 1.58/1.50 1.8 4
125 0.24 1.89/1.80 1.7 4
160 0.28 2.31/2.20 1.6 4
200 0.34 2.73/2.60 1.5 4
250 0.40 3.2/3.05 1.4 4
315 0.48 3.83/3.65 1.4 4
400 0.57 4.52/4.30 1.3 4
500 0.68 5.41/5.15 1.2 4
630 0.81 6.20 1.1 4.5
800 0.98 7.50 1.0 4.5
1000 1.15 10.30 1.0 4.5
1250 1.36 12.00 0.9 4.5
1600 1.64 14.50 0.8 4.5

10KV level ZGS13-H(Z) Combined transformer technology parameters
nominal capacity(KVA) Voltage combination Join group label No-load loss(KW)  load loss(KW) No-load current(%) Short circuit impedance
HV(KV) High voltage range LV(KV)
50 6
6.3
6.6
10
10.511
±5% 0.4 Dyn11/Yyn0 1.10 0.91/0.87 2.0 4
63 0.11 1.09/1.04 1.9 4
80 0.13 1.31/1.25 1.9 4
100 0.15 1.58/1.50 1.8 4
125 0.17 1.89/1.80 1.7 4
160 0.20 2.31/2.20 1.6 4
200 0.24 2.73/2.60 1.5 4
250 0.29 3.2/3.05 1.4 4
315 0.34 3.83/3.65 1.4 4
400 0.41 4.52/4.30 1.3 4
500 0.48 5.41/5.15 1.2 4
630 0.57 6.20 1.1 4.5
800 0.70 7.50 1.0 4.5
1000 0.83 10.30 1.0 4.5
1250 0.97 12.00 0.9 4.5